AP-1 cargo read-back

Take 32 archived designs to 128 clonal wells, mark each well so sequencing says which well it came from, and call a pass or a fail per well.

Designs
32 of 72 on the sheet
Route
index PCR
Wells
128 over 1 picked plate
Selection
kanamycin

Have in hand

  • AP-1 cargo archive plate one clonal stock a design, 72 of them, sealed and frozen
  • Barcoded index primer plate the lab's index primer plate IDX-01, prepared once and called for by a run · 1 µM each

Leaves you with

  • clonal picked plate one well a picked colony, each well one clone
  • well calls a pass or a fail a well, and which design each well holds

Keep in mind

A design is read back as a name and a count of the pieces it was built from, never as bases, so any clonal stock this lab holds can be read back here.

The bench is sized from the 32 designs read and not from the sheet, so a design the floor leaves out costs no well, no plate and no reagent.

0 of 6 steps done

Which designs are read back

This run reads every design built from 2 fragments or more: 32 of 72. The rest stay polyclonal and are never read one design at a time.

Every design is spotted from AP-1 cargo archive plate, which this run reads a copy of and never changes. A design whose spot grows nothing has no clone to read, and is re-transformed before anyone re-synthesises it.

How a well is told from the rest

The index PCR route marks each well: amplify each well with one barcoded primer pair. The other route marks the same wells a different way, and the picking, the pass rule and the reformat are the same either way.

A well's marks are worked out from where the well is rather than looked up, so a demultiplexer can check an address instead of trusting a file. One axis of the address is the plate: this run pools 2 plates, and the marks tell 96 plates apart on one flow cell.

A well is called above 20 reads. The other route's floor is not a stricter or a looser setting of the same scale, so neither number carries over to the other route.

Materials

NameSupplierCatalogueStoragePer runNoteSource
25 cm BioAssay plateCorning431111one spot a designkanamycin; about 2,500 colonies a plate[1]
384-well culture plateBeckman Coulterc742901, one a 384 wells60 µL low-salt LB with kanamycin a well[1]
96-well half-skirted PCR plateUSA Scientific1402-97002, one a quarter of a picked plate[2]
Barcoded index primer plate-20 °C2 µL a well at 1 µM each, 96 forward and 96 reverseprepared once as lab stock, by its own protocol; a run calls for it. The SI's plate preparation ends at 0.1 µM, where its own protocol and the article both stamp 1 µM, which is what this takes[2]
ThermoPol Reaction BufferNEBB9004-20 °C1 µL a reaction, 10X[2]
dNTP mixNEBN0447-20 °C0.2 µL a reaction, 10 mM each[2]
Taq DNA PolymeraseNEBM0267-20 °C0.05 µL a reaction5 U/µL, so one reaction takes 0.25 units[3]
DMSO, molecular biology gradeMP Biomedicals1948190.4 µL a reaction, 4% (v/v) in the well[2]

Equipment: QPix XE Microbial Colony Picker, multichannel pipette on 96-well spacing, Thermocycler taking a 96-well plate, Incubator at 37 °C, A sequencer, and a demultiplexer that can check an address

Caution: Keep the polymerase on ice.

Plates

picked 1123456789101112131415161718192021222324ABCDEFGHIJKLMNOP
picked 1 384 wells · 2 kinds · Beckman Coulter #c74290 · one picked colony each in 60 µL low-salt LB with kanamycin · 128 of 384 wells picked, a quarter at a time
  • quarter 1
  • quarter 2
index 1123456789101112ABCDEFGH
index 1 96 wells · 96 kinds · USA Scientific #1402-9700 · one barcoded PCR each, the pair its own address names · plate mark 1; 96 of 96 wells used
index 2123456789101112ABCDEFGH
index 2 96 wells · 32 kinds · USA Scientific #1402-9700 · one barcoded PCR each, the pair its own address names · plate mark 2; 32 of 96 wells used

Array and pick

Expected result

  • One spot a design, at about 2,500 colonies a plate, which is the density picking wants.

Troubleshooting

A spot grows nothing
That design has no clone to read. Re-transform it from the archive before anyone re-synthesises it.

Notes

  • This run reads back every design in 2 fragments or more: 32 designs. The rest stay polyclonal and are never read one design at a time.
  • The archive is untouched: this reads a copy of it.

Expected result

  • 128 wells over 1 plate: 128 picked.
  • Every colony of one design sits on one plate.

Troubleshooting

A design in many fragments gives no clean colony
The chances above say which designs that is likeliest for. Pick more colonies of those designs before the plates are poured, not after.

Notes

  • 4 colonies a design is the only count measured: four gave a clean copy of 343 of 458 genes.[4]
  • 2 fragments: 16 designs, 100.0% of picks clean
  • 3 fragments: 6 designs, 93.8% of picks clean
  • 4 fragments: 9 designs, 89.2% of picks clean
  • 5 fragments: 1 design, 84.6% of picks clean
  • A quarter at a time is what makes a part-filled plate give full plates downstream, and what keeps a mark off a plate that is mostly empty.

Mark every well

Sample a quarter of picked 1 into index 1 multichannel pipette · 96 moves · 1 µL each · every other row and column, starting A1 · one well in four, which is the spacing a head built for the index format reads[2]
From picked 1123456789101112131415161718192021222324ABCDEFGHIJKLMNOP
Into index 1123456789101112ABCDEFGH
96 moves
FromToµL
picked 1 A1index 1 A11
picked 1 A3index 1 A21
picked 1 A5index 1 A31
picked 1 A7index 1 A41
picked 1 A9index 1 A51
picked 1 A11index 1 A61
picked 1 A13index 1 A71
picked 1 A15index 1 A81
picked 1 A17index 1 A91
picked 1 A19index 1 A101
picked 1 A21index 1 A111
picked 1 A23index 1 A121
picked 1 C1index 1 B11
picked 1 C3index 1 B21
picked 1 C5index 1 B31
picked 1 C7index 1 B41
picked 1 C9index 1 B51
picked 1 C11index 1 B61
picked 1 C13index 1 B71
picked 1 C15index 1 B81
picked 1 C17index 1 B91
picked 1 C19index 1 B101
picked 1 C21index 1 B111
picked 1 C23index 1 B121
picked 1 E1index 1 C11
picked 1 E3index 1 C21
picked 1 E5index 1 C31
picked 1 E7index 1 C41
picked 1 E9index 1 C51
picked 1 E11index 1 C61
picked 1 E13index 1 C71
picked 1 E15index 1 C81
picked 1 E17index 1 C91
picked 1 E19index 1 C101
picked 1 E21index 1 C111
picked 1 E23index 1 C121
picked 1 G1index 1 D11
picked 1 G3index 1 D21
picked 1 G5index 1 D31
picked 1 G7index 1 D41
picked 1 G9index 1 D51
picked 1 G11index 1 D61
picked 1 G13index 1 D71
picked 1 G15index 1 D81
picked 1 G17index 1 D91
picked 1 G19index 1 D101
picked 1 G21index 1 D111
picked 1 G23index 1 D121
picked 1 I1index 1 E11
picked 1 I3index 1 E21
picked 1 I5index 1 E31
picked 1 I7index 1 E41
picked 1 I9index 1 E51
picked 1 I11index 1 E61
picked 1 I13index 1 E71
picked 1 I15index 1 E81
picked 1 I17index 1 E91
picked 1 I19index 1 E101
picked 1 I21index 1 E111
picked 1 I23index 1 E121
picked 1 K1index 1 F11
picked 1 K3index 1 F21
picked 1 K5index 1 F31
picked 1 K7index 1 F41
picked 1 K9index 1 F51
picked 1 K11index 1 F61
picked 1 K13index 1 F71
picked 1 K15index 1 F81
picked 1 K17index 1 F91
picked 1 K19index 1 F101
picked 1 K21index 1 F111
picked 1 K23index 1 F121
picked 1 M1index 1 G11
picked 1 M3index 1 G21
picked 1 M5index 1 G31
picked 1 M7index 1 G41
picked 1 M9index 1 G51
picked 1 M11index 1 G61
picked 1 M13index 1 G71
picked 1 M15index 1 G81
picked 1 M17index 1 G91
picked 1 M19index 1 G101
picked 1 M21index 1 G111
picked 1 M23index 1 G121
picked 1 O1index 1 H11
picked 1 O3index 1 H21
picked 1 O5index 1 H31
picked 1 O7index 1 H41
picked 1 O9index 1 H51
picked 1 O11index 1 H61
picked 1 O13index 1 H71
picked 1 O15index 1 H81
picked 1 O17index 1 H91
picked 1 O19index 1 H101
picked 1 O21index 1 H111
picked 1 O23index 1 H121
Sample a quarter of picked 1 into index 2 multichannel pipette · 32 moves · 1 µL each · every other row and column, starting A2 · one well in four, which is the spacing a head built for the index format reads[2]
From picked 1123456789101112131415161718192021222324ABCDEFGHIJKLMNOP
Into index 2123456789101112ABCDEFGH
32 moves
FromToµL
picked 1 A2index 2 A11
picked 1 A4index 2 A21
picked 1 A6index 2 A31
picked 1 A8index 2 A41
picked 1 A10index 2 A51
picked 1 A12index 2 A61
picked 1 A14index 2 A71
picked 1 A16index 2 A81
picked 1 A18index 2 A91
picked 1 A20index 2 A101
picked 1 A22index 2 A111
picked 1 A24index 2 A121
picked 1 C2index 2 B11
picked 1 C4index 2 B21
picked 1 C6index 2 B31
picked 1 C8index 2 B41
picked 1 C10index 2 B51
picked 1 C12index 2 B61
picked 1 C14index 2 B71
picked 1 C16index 2 B81
picked 1 C18index 2 B91
picked 1 C20index 2 B101
picked 1 C22index 2 B111
picked 1 C24index 2 B121
picked 1 E2index 2 C11
picked 1 E4index 2 C21
picked 1 E6index 2 C31
picked 1 E8index 2 C41
picked 1 E10index 2 C51
picked 1 E12index 2 C61
picked 1 E14index 2 C71
picked 1 E16index 2 C81

Expected result

  • 2 index plates, 128 reactions in all.

Notes

  • One well in four lines up under a head built for the smaller format, so a quarter moves in one pass.

Caution: Keep the polymerase on ice.

Index PCR, one well a sample
mix includes 50% extra
ComponentStockFinal1 rxn (µL)Mix for 128 (µL)
ThermoPol Reaction Buffer[2]10X1X1192
dNTP mix[2]10 mM each0.2 mM each0.238.4
Taq DNA Polymerase[2]5 U/µL0.25 units0.059.6
DMSO[2]100%4% (v/v)0.476.8
Nuclease-free water[2]5.351,027
Barcoded primer mix[2]1 µM each0.2 µM each2each tube
Overnight culture[2]1each tube
Total101,344
mix only

Put 7 µL of mix in each tube, then add 2 µL Barcoded primer mix, 1 µL Overnight culture.

Index PCR · 1 h 35 min plus ramps[2]
StepTemperatureTimeCycles
Initial denaturation95 °C5 min1
Denature95 °C20 s×10
Anneal68 → 63.5 °C
-0.5 °C a cycle
20 s
Extend68 °C2 min
Denature95 °C20 s×25
Anneal and extend68 °C2 min
Final extension68 °C5 min1
Hold4 °C∞1

Expected result

  • One barcoded amplicon a well. A well's own place in the plate names its forward mark — the first well the first mark — and every well of one plate takes that plate's own reverse mark.
  • One band a well, the design plus about 100 bp: the two marks, and the stretch between the primer sites and the reading frame.

Troubleshooting

A plate reads back far fewer wells than the others
LevSeq traces that to the amplification, not the sequencing: on a run of ten plates three returned under 60% of their variants. Check each pool on a gel before the library prep.

Notes

  • 96 forward marks and 96 reverse reach 9,216 wells, so the pairs already held cover far more than this run needs.
  • The primer plate is built once as lab stock and a run calls for it; this protocol does not build one.
  • The first 10 cycles touch down from 68 to 63.5 °C, 0.5 °C a cycle, and 25 more run at 68 °C.
  • Extension is 2 minutes, what the authors ran for a gene below 1 kb. The published rule is at least one minute a kilobase, so a longer design wants it raised.
  • The mix is made 1.5 times what the wells take, which is what LevSeq's own per-plate table spells out. Nothing says what the surplus is for.

Expected result

  • Reads for 128 wells, every well told from the rest by the marks it carries.

Notes

  • This read pools 2 plates. One axis of the address is the plate, so the marks tell 96 plates apart on one flow cell.

Call the wells

Expected result

  • A well read more than 20 times is called; the index PCR route tolerates 10 reads and warns between the two.
  • A pass matches across the whole designed region: both entry overhangs, the fragment, the stuffer and the barcode.

Troubleshooting

A well's call is the right protein and the wrong barcode
It fails. A barcode that no longer names its member cannot be put right by the linkage read later.

Notes

  • A well read too thinly carries no verdict and is not a failure, so reformatting does not compact it out.
  • More than one consensus is mixed, and mixed fails.
  • A design with no passing well is picked again from the same archive spot before anyone re-synthesises it.

Sources

  1. Qian et al. 2026, Supplementary Information · Nat. Commun. 10.1038/s41467-026-76740-9 · held under reference_docs/ · 2026-10-06 https://doi.org/10.1038/s41467-026-76740-9 cited at Day 2 · Day 3
  2. Long, Y. et al. 2025, LevSeq, Supporting Information · held under reference_docs/ · 2026-10-06 https://doi.org/10.1021/acssynbio.4c00625 cited at step 2 · step 3 · step 1 · step 4 · thermal cycler table
  3. New England Biolabs, Product Specification: Taq DNA Polymerase with ThermoPol Buffer · PS-M0267S/L/X/E v2.0, effective 12 Feb 2020 · plain curl · 2026-10-08 · docs/research/route-b-index-pcr.md https://www.neb.com/en/-/media/catalog/specifications/m/0/m0267s_l_x_e_v2.pdf cited at Concentration
  4. Lund, S. et al. (2024) Highly parallelized construction of DNA from low-cost oligonucleotide mixtures using Data-optimized Assembly Design and Golden Gate. ACS Synth. Biol. 13, 745-751 · docs/research/synthesis-and-assembly.md https://doi.org/10.1021/acssynbio.3c00694 cited at colonies screened per gene